Notebook, 7" x 9", soft black cover, spine broken, of rough laboratory notes. Includes:
p.1 calculations; Cailletet's values for tensions
p.2 notes on galvanometer
pp.3-5 experiments with Cailletet apparatus
p.6 correction of manometer on Cailletet apparatus
pp.7-22 experiments with Cailletet apparatus, including determination of density of CO2, and liquefaction of nitrous oxide.
p.23 calibration of Cailletet tube
p.24 liquefaction of mixture of CO2 and N2O
p.25 calibration of Cailletet tube for determining specific gravity of CO2 at different temperatures
p.26 specific gravity of CO2 at 21°C
pp.27-31 density of CO2.
pp.32-38 density of liquid CO2.
pp.39-40 blank
pp.41-68 density of liquid CO2.
pp.69-71 blank
pp.72-4 calibration of capillary tube
pp.75-94 readings and densities obtained from tube
p.95 densities obtained from narrow tube
pp.96-104 calibration of capillary tube for use as air manometer
pp.105-33 CO2 liquid density
p.133 tensions of liquid CO2 at different temperatures
p.134 densities from narrow tube
p.135 CO2 liquid density
pp.136-50 compression of liquid CO2.
pp.150-51 determination of coefficient of compression of liquid CO2 at different temperatures
p.152 average coefficients of compression of CO2 liquid at different temperatures.
p.153 comparison of his own liquid CO2 tensions with those obtained by Andrews.
p.154 blank
pp.155-6 calibration of tube and reservoir to be used for CO2 1 Nov. 1878
pp.157-60 compression of liquid CO2 4 Nov.
p.161-3 experiments to test purity of CO2 6 Nov.
p.164 coefficients of compression of liquid CO2 at different temperatures, the pressure being constant
p.165 experiments to test purity of CO2, using same tube as on p.161.
p.166-7 coefficients of compression of liquid CO2 at different temperatures, the pressure being constant
p.168 coefficients of compression of liquid CO2 at different temperatures and pressures, the volume remaining constant.
p.169 coefficients of compression at points on a horizontal line drawn through the iso-thermals, the initial volume being the same.
pp.170-7 experiments on the compressibility of water, made in the capillary tube used in the last liquid CO2 compressions, to find out how much was due to the expansibility of the tube; beginning 25 Nov. 1878.
p.178 comparison between Grassi's coefficients and his own.
pp.179-83 blank
pp.184-87 liquefaction and compression of acetylene, Feb. 1879.
pp.188-9 determination of critical point (acetylene).
pp.190-1 blank
pp.192-9 density determinations of liquid acetylene
p.200 18 Feb. 1879: re-erection of manometer and acetylene tubes
pp.201-4 density determinations of liquid acetylene
pp.205-6 blank
pp.207-11 compression of liquid acetylene at different temperatures 19 Feb. 1879.
p.212 air manometer for low pressures; 25 Feb. 1879
p.213 tensions of liquid acetylene at different temperatures; 25 Feb. 1879.
pp.214-5 coefficients of compression of liquid acetylene at different temperatures, the pressure being the same.
p.215 coefficients of compression at different temperatures and pressures, the volume remaining the same (liquid C2H2 and C6 H6 at different temperatures; coefficients of
p. compression at different temperatures but the same initial volume
pp.217-29 blank
pp.230-5 experiments to see if CO2 gas could be obtained free from air
p.236 blank
p.237 sensitiveness of kilogram balance
p.238 note of contents of volume
-
Held by (Who holds the record)
- Royal Institution of Great Britain
-
Language (The language of the record)
- English
-
Physical description (The amount and form of the record)
- 238 pp
-
Record URL
- https://beta.nationalarchives.gov.uk/catalogue/id/0d90d1e1-f5bc-4a9f-8950-c71fbd2af5ec/
Series information
DEWAR/Box DB5a
Low Temperature Work
See the series level description for more information about this record.
Catalogue hierarchy
This record is held at Royal Institution of Great Britain
Within the fonds: DEWAR
Papers of James Dewar
Within the series: DEWAR/Box DB5a
Low Temperature Work
You are currently looking at the file: DEWAR/DB5a/1
[?G.Ansdell]